Why Use a Point, Not a Tangent, for Non-Ohmic Resistance?
At a glance
- 1. Choose the operating point
Read the voltage and current values at the condition you want to describe.
- 2. Find the point resistance
Divide the voltage by the current to get the ratio resistance at that operating point.
- 3. Use a tangent for changes
The tangent slope gives differential resistance: how much voltage changes for a small current change.
- 4. Check the graph axes
For voltage versus current, slope is resistance; for current versus voltage, slope is conductance.
For an ohmic conductor, resistance is constant: doubling the voltage doubles the current. Its voltage-versus-current graph is a straight line through the origin, and the ratio is the same as the graph’s slope.
A non-ohmic conductor does not have one constant resistance across all operating conditions. If you want its resistance at a particular voltage and current, use the ratio at that point. A tangent is useful too, but it answers a different question: how much the voltage changes when the current changes slightly.
Two meanings of resistance
Suppose the graph has current on the horizontal axis and voltage on the vertical axis. At a point on the curve, the point resistance (also called the static or secant resistance) is
Geometrically, this is the slope of the straight line from the origin to that point—not the slope of the curve itself there.
The tangent slope is the differential resistance:
It measures the local change in voltage per change in current. For a small change around an operating point, , provided the curve is smooth and the change is small enough.
These quantities need not be equal. Point resistance describes the voltage-to-current ratio at the operating point; differential resistance describes the response to a small perturbation around it. Neither is universally the only meaning of “resistance”—the intended meaning depends on what you are calculating.
Worked example
Consider a non-ohmic device whose voltage-current relation is
where voltage is in volts and current is in amperes. At , its voltage is
Its point resistance is therefore
To find the tangent slope, differentiate the relation:
At , the differential resistance is . So at this operating point the device has a point resistance of and a differential resistance of . The first is the ratio of the measured voltage to current; the second predicts the voltage change for a small current change near .
Why the distinction matters
If you are asked for the resistance at a stated operating point, the usual interpretation is . For example, this is the resistance relevant to calculating the ratio between the voltage and current at that condition.
If you are analyzing a small signal or a small change around a bias point, use the tangent slope . This is common when studying how a nonlinear component responds to a small added signal. It is also useful in circuit models that approximate a nonlinear device locally by a linear one.
For an ohmic conductor, . The graph is a straight line through the origin, so its secant slope and tangent slope are both . That is why the distinction often goes unnoticed when first learning Ohm’s law.
If the graph instead puts current on the vertical axis and voltage on the horizontal axis, its tangent slope is , which is differential conductance. The differential resistance is then , the reciprocal slope when the derivative is finite and nonzero. Always check the axes before interpreting a graph’s slope.
Common mistakes
- Calling the tangent slope the point resistance: It is differential resistance, not generally .
- Using a graph’s slope without checking its axes: A -versus- slope has resistance units; an -versus- slope has conductance units.
- Assuming a non-ohmic device has one fixed resistance: Its point resistance can change with the operating point. For devices such as filament lamps, temperature can also change as the current changes, so measurements must refer to the actual operating conditions.
- Treating “non-ohmic” as meaning resistance cannot be calculated: You can calculate at any nonzero operating point; it simply may not stay constant as conditions change.
References
- David Halliday, Robert Resnick, and Jearl Walker, Fundamentals of Physics
Spotted an error? Send a correction. Read how we write and check articles in our editorial policy.