Ph · Physics

Why Can a Variable Potential Divider Reduce Current to Zero?

Published By the 9to5Science editorial team

At a glance

  1. 1. Identify the wiring

    A potential divider has its two end terminals across the supply and its load connected between the wiper and a reference terminal.

  2. 2. Move the wiper

    The wiper selects a point along the resistor track, changing the output voltage relative to the reference.

  3. 3. Reach the endpoint

    At the grounded end, the wiper and reference are at the same potential, so the load voltage is zero.

  4. 4. Separate the currents

    The load current can be zero even though current still flows through the potential divider track.

Advertisement

A variable potential divider can reduce the current through a load to zero because it varies the voltage across that load, not just the total resistance in series with it. With the usual wiring, the load is connected between the potentiometer’s moving contact (the wiper) and one end of its track. At the grounded end, those two connections are at the same potential, so there is no voltage to drive current through the load.

That does not mean all current in the circuit stops. Current can continue to flow through the divider’s resistor track.

How a potential divider is wired

A potentiometer has two fixed terminals at the ends of a resistive track and a moving wiper. Connect the fixed terminals across a voltage supply, and the wiper provides an adjustable output voltage. If the lower fixed terminal is grounded, the output is normally measured between the wiper and ground, with the load connected across those same points.

Moving the wiper changes the amount of resistance above and below it. With no load connected, the output voltage is proportional to the wiper’s position. At the grounded end, the output is zero; at the supply end, it is equal to the supply voltage.

The load current follows the voltage across the load. For a resistive component,

Iload=VloadRload.I_{\text{load}}=\frac{V_{\text{load}}}{R_{\text{load}}}.

Thus, if the wiper is at ground and the load is connected from the wiper to ground, then Vload=0V_{\text{load}}=0 and Iload=0I_{\text{load}}=0 in the ideal circuit.

Why the divider itself can still draw current

The load and the divider track are separate paths. At the grounded end, the load is connected between two points at the same voltage, so no current passes through it. But the supply is still connected across the full potentiometer track, so current can flow through that track.

For example, connect a 10 kΩ10\,\text{k}\Omega potentiometer across an ideal 12 V12\,\text{V} supply. Its track current is

Itrack=12 V10 kΩ=1.2 mA.I_{\text{track}}=\frac{12\,\text{V}}{10\,\text{k}\Omega}=1.2\,\text{mA}.

If a load is connected between the wiper and the grounded end, setting the wiper at that end gives the load zero volts and zero current. The 1.2 mA1.2\,\text{mA} through the track does not have to pass through the load.

Worked example: a loaded divider

Suppose the same 10 kΩ10\,\text{k}\Omega potentiometer is set halfway, so the track is split into two 5 kΩ5\,\text{k}\Omega sections. Connect a 1 kΩ1\,\text{k}\Omega load between the wiper and ground. The load is in parallel with the lower 5 kΩ5\,\text{k}\Omega section, so the lower equivalent resistance is

Rlower=(5 kΩ)(1 kΩ)5 kΩ+1 kΩ=0.833 kΩ.R_{\text{lower}}=\frac{(5\,\text{k}\Omega)(1\,\text{k}\Omega)}{5\,\text{k}\Omega+1\,\text{k}\Omega}=0.833\,\text{k}\Omega.

The output voltage is then the voltage across that equivalent resistance:

Vout=12 V 0.8335+0.833≈1.71 V.V_{\text{out}}=12\,\text{V}\,\frac{0.833}{5+0.833}\approx1.71\,\text{V}.

The load current is about

Iload=1.71 V1 kΩ=1.71 mA.I_{\text{load}}=\frac{1.71\,\text{V}}{1\,\text{k}\Omega}=1.71\,\text{mA}.

The output is not 6 V6\,\text{V}, the unloaded halfway value, because the load changes the effective resistance of the lower section. But when the wiper reaches the grounded end, the output voltage across the load becomes zero in the ideal circuit, and so does its current.

Why a series variable resistor behaves differently

A variable resistor (rheostat) is commonly connected in series with a load. In that arrangement, the supply voltage is shared between the resistor and the load. Increasing the rheostat’s resistance reduces the current, but a finite resistance does not normally make it exactly zero:

I=VsupplyRload+Rrheostat.I=\frac{V_{\text{supply}}}{R_{\text{load}}+R_{\text{rheostat}}}.

For a nonzero supply voltage and a positive, finite total series resistance, this current is nonzero. It reaches zero only if the circuit is opened (effectively infinite resistance), or if the supply voltage is zero. A potential divider can instead make the load’s voltage zero by setting both of its terminals to the same potential.

Common mistakes

  • Assuming the load current is the divider current. They are currents in different branches; the track may draw current while the load draws none.
  • Treating a loaded divider as unloaded. A load connected from wiper to ground is in parallel with the lower part of the track and can change the output voltage.
  • Confusing a divider with a series rheostat. A divider sets an output voltage relative to a reference; a series rheostat changes the resistance in the load’s current path.
  • Assuming every real setup reaches exact zero. In an ideal circuit, the wiper at the grounded endpoint gives zero output. Real contacts, wiring, leakage, and offsets can leave a small residual voltage or current. A component with its own internal source also needs separate analysis; zero terminal voltage does not by itself guarantee zero current in every possible device.

Spotted an error? Send a correction. Read how we write and check articles in our editorial policy.