Ch · Chemistry

How to Understand and Use the Arrhenius Equation

Published By the 9to5Science editorial team

At a glance

  1. 1. Write the equation

    Relate the rate constant to temperature, the activation energy, and the pre-exponential factor.

  2. 2. Use kelvin

    Convert temperatures to kelvin and keep energy units consistent with the gas constant.

  3. 3. Choose a calculation

    Use one-temperature data, two-temperature data, or a plot of logarithmic rate constants.

  4. 4. Check assumptions

    Interpret the result over a range where the reaction mechanism and Arrhenius behavior remain valid.

The Arrhenius equation describes how a chemical reaction’s rate constant changes with temperature. It is useful for estimating how much faster a reaction will become when warmed, or for finding an apparent activation energy from rate measurements. The equation is empirical, but its exponential form has a useful molecular interpretation.

The Arrhenius equation

The usual form is

k=Ae−Ea/(RT)k=Ae^{-E_a/(RT)}

Here, kk is the reaction’s rate constant, AA is the pre-exponential factor (also called the frequency factor), EaE_a is the activation energy, RR is the molar gas constant, and TT is absolute temperature in kelvin. If you use R=8.314 J mol−1 K−1R=8.314\ \mathrm{J\,mol^{-1}\,K^{-1}}, express EaE_a in joules per mole. Alternatively, use R=0.008314 kJ mol−1 K−1R=0.008314\ \mathrm{kJ\,mol^{-1}\,K^{-1}} with EaE_a in kilojoules per mole.

The units of AA are the same as the units of kk. Those units depend on the reaction-rate law: for example, a first-order rate constant has units of inverse time, while a second-order rate constant commonly has units of concentration-inverse time.

As TT increases, the exponent −Ea/(RT)-E_a/(RT) becomes less negative, so kk increases. In a simple molecular picture, more molecules have enough energy to reach a reactive configuration. The parameter AA accounts for factors such as collision frequency and the likelihood that collisions have a productive orientation. This picture is helpful, but the Arrhenius equation is usually applied as a model fitted to experimental data.

Calculate a rate constant at one temperature

If AA and EaE_a are known, substitute them along with the temperature in kelvin. For instance, suppose a reaction has A=2.0×1010 s−1A=2.0\times10^{10}\ \mathrm{s^{-1}}, Ea=50.0 kJ mol−1E_a=50.0\ \mathrm{kJ\,mol^{-1}}, and you want kk at 300 K300\ \mathrm{K}. Use R=0.008314 kJ mol−1 K−1R=0.008314\ \mathrm{kJ\,mol^{-1}\,K^{-1}}:

k=(2.0×1010)exp⁡(−50.00.008314×300) s−1≈3.9×101 s−1.\begin{aligned} k&=(2.0\times10^{10})\exp\left(-\frac{50.0}{0.008314\times300}\right)\ \mathrm{s^{-1}}\\ &\approx 3.9\times10^1\ \mathrm{s^{-1}}. \end{aligned}

This gives the rate constant, not automatically the reaction rate. To find the rate, you also need the rate law and the concentrations. For a first-order reaction, for example, rate=k[A]\text{rate}=k[A].

Estimate activation energy from two temperatures

If you know the rate constants at two temperatures, divide the Arrhenius equation at one temperature by the equation at the other. Taking natural logarithms gives

ln⁡(k2k1)=EaR(1T1−1T2).\ln\left(\frac{k_2}{k_1}\right)=\frac{E_a}{R}\left(\frac{1}{T_1}-\frac{1}{T_2}\right).

Therefore,

Ea=Rln⁡(k2/k1)(1/T1)−(1/T2).E_a=R\frac{\ln(k_2/k_1)}{(1/T_1)-(1/T_2)}.

For a concrete example, let k1=0.020 s−1k_1=0.020\ \mathrm{s^{-1}} at T1=300 KT_1=300\ \mathrm{K} and k2=0.050 s−1k_2=0.050\ \mathrm{s^{-1}} at T2=320 KT_2=320\ \mathrm{K}. Then

Ea=8.314ln⁡(0.050/0.020)(1/300)−(1/320) J mol−1≈3.66×104 J mol−1=36.6 kJ mol−1.\begin{aligned} E_a&=8.314\frac{\ln(0.050/0.020)}{(1/300)-(1/320)}\ \mathrm{J\,mol^{-1}}\\ &\approx 3.66\times10^4\ \mathrm{J\,mol^{-1}}\\ &=36.6\ \mathrm{kJ\,mol^{-1}}. \end{aligned}

This is an apparent activation energy based on those measurements. The calculation assumes the same reaction pathway and rate-law regime apply at both temperatures.

Use an Arrhenius plot

Taking the natural logarithm of the equation gives a straight-line form:

ln⁡k=ln⁡A−EaR1T.\ln k=\ln A-\frac{E_a}{R}\frac{1}{T}.

Plot ln⁡k\ln k on the vertical axis against 1/T1/T on the horizontal axis. If the data follow Arrhenius behavior, a linear fit has slope m=−Ea/Rm=-E_a/R and intercept b=ln⁡Ab=\ln A. Thus Ea=−mRE_a=-mR, and A=ebA=e^b. If the horizontal axis is instead 1000/T1000/T, account for the factor of 1000 when converting the slope to EaE_a.

A fit using several measurements is generally more informative than a two-point estimate, because it shows whether the data are approximately linear and reduces reliance on any single measurement. Use the same logarithm convention throughout: the equations above use the natural logarithm, ln⁡\ln. A base-10 plot has a different slope, with the factor 2.3032.303 included in the conversion.

Common mistakes

  • Using Celsius: Convert to kelvin first: T(K)=T(∘C)+273.15T(\mathrm{K})=T(^{\circ}\mathrm{C})+273.15. Do not put Celsius values into the equation.
  • Mixing units: Pair EaE_a in joules per mole with R=8.314 J mol−1 K−1R=8.314\ \mathrm{J\,mol^{-1}\,K^{-1}}, or pair kilojoules per mole with R=0.008314 kJ mol−1 K−1R=0.008314\ \mathrm{kJ\,mol^{-1}\,K^{-1}}.
  • Reversing the temperature terms: In the two-temperature formula, keep the order consistent with the rate ratio. If T2>T1T_2>T_1 and k2>k1k_2>k_1, the calculated EaE_a should be positive.
  • Confusing kk with rate: The Arrhenius equation predicts how the rate constant depends on temperature. The reaction rate also depends on reactant concentrations.
  • Assuming every reaction stays linear: Changes in mechanism, phase, or other conditions can cause departures from a straight Arrhenius plot. A fitted activation energy may then depend on the temperature range.

References

  1. Physical Chemistry, 11th edition — Peter Atkins, Julio de Paula, and James Keeler
  2. Chemical Kinetics, 3rd edition — Keith J. Laidler

Spotted an error? Send a correction. Read how we write and check articles in our editorial policy.